Enfora MT2500: Difference between revisions
Jump to navigation
Jump to search
No edit summary |
|||
(18 intermediate revisions by the same user not shown) | |||
Line 1: | Line 1: | ||
== Anschlüsse == |
|||
Der Stecker ist Molex Bestellnummer '''43025-1600''' und die passenden Kontakte dazu sind Molex Bestellnummer '''43030-0008'''. |
|||
⚫ | |||
⚫ | |||
{| |
|||
⚫ | |||
!Pin |
|||
⚫ | |||
!Signal |
|||
|- |
|||
|1 |
|||
|Mic + (Differential Audio Input) |
|||
|- |
|||
|2 |
|||
|Mic - (Differential Audio Input) |
|||
|- |
|||
|3 |
|||
|Ignition Sense |
|||
|- |
|||
|4 |
|||
|USB D+ |
|||
|- |
|||
|5 |
|||
|USB D- |
|||
|- |
|||
|6 |
|||
|Ground |
|||
|- |
|||
|7 |
|||
|GPO5 (General Purpose Output) |
|||
|- |
|||
|8 |
|||
|GPO2 (General Purpose Output) |
|||
|- |
|||
|9 |
|||
|EARP (Differential Audio Output) |
|||
|- |
|||
|10 |
|||
|EARN (Differential Audio Output) |
|||
|- |
|||
|11 |
|||
|Power Input (9-16 VDC) |
|||
|- |
|||
|12 |
|||
|USB Vbus |
|||
|- |
|||
|13 |
|||
|GPI1 (General Purpose Digital Input) |
|||
|- |
|||
|14 |
|||
|GPO3 (Latched General Purpose Output) |
|||
|- |
|||
|15 |
|||
|A/D IN 2 (Dual Function Input) (Operation as Analog 0-16V or Digital Input is Configured via AT Command) |
|||
|- |
|||
|16 |
|||
|A/D IN 1 (Analog Input 0-16V) |
|||
|- |
|||
|} |
|||
Die USB Abschirmung und die Masse sollen mit pin 6 (ground) verbunden werden, die Positive USB Leitung wird an Pin 12(Vbus) angeschlossen. |
|||
⚫ | |||
⚫ | |||
* [[File:GSM2418UG001 - MT 2500 User Guide.pdf]] |
|||
* [[File:AT-Commands.pdf]] |
|||
* [[File:Programmingenfora.pdf]] |
|||
== Erkenntnisse == |
|||
* Auf dem Tracker ist ein Kleber der sagt dass man das Gerät an die Stromversorgung anschliessen muss bevor man den USB Stecker einsteckt. Es geht nichts kaputt wenn man diesen Hinweis nicht beachtet, aber der Tracker startet im Firmware upload Modus. |
|||
* Der tracker emuliert drei serielle CDC Schnittstellen, leider funktionieren diese nur mit Windows, weil das Linux Modul die USB ID nicht kennt(?) |
|||
* Der erste serielle Port wird für debug informationen benutzt, am zweiten Port kann das Gerät programmiert werden. Der zweck des dritten Ports ist nicht bekannt. |
|||
* Der Tracker dürfte mit dem internen Akku zwischen 3h (GPS und GSM im dauerbetrieb) und 14h (GPS und GSM im standby) laufen. |
|||
== Programmierung == |
|||
Ein Positionsupdate alle 60s oder 100m schicken: |
|||
<pre> |
|||
at&f |
|||
at&w |
|||
at+cgdcont=1,"IP","internet","",0,0 |
|||
at%cgpco=1,"new,new",0 |
|||
at$friend=1,1,"Dest IP" |
|||
at$udpapi=,Dest Port |
|||
at$wakeup=0,1 |
|||
at$evtim1=60 |
|||
at$evtim2=1200 |
|||
at$event=12,1,12,1,1 |
|||
at$event=12,3,40,0,4350 |
|||
at$event=13,0,16,100,1000000 |
|||
at$event=13,3,43,2,0 |
|||
at$event=13,3,40,0,4350 |
|||
AT$areg=2 |
|||
at&w |
|||
</pre> |
|||
[...] |
|||
[[Category:Hardware]] |
[[Category:Hardware]] |
Latest revision as of 19:59, 19 July 2014
Anschlüsse
Der Stecker ist Molex Bestellnummer 43025-1600 und die passenden Kontakte dazu sind Molex Bestellnummer 43030-0008.
Pin | Signal |
---|---|
1 | Mic + (Differential Audio Input) |
2 | Mic - (Differential Audio Input) |
3 | Ignition Sense |
4 | USB D+ |
5 | USB D- |
6 | Ground |
7 | GPO5 (General Purpose Output) |
8 | GPO2 (General Purpose Output) |
9 | EARP (Differential Audio Output) |
10 | EARN (Differential Audio Output) |
11 | Power Input (9-16 VDC) |
12 | USB Vbus |
13 | GPI1 (General Purpose Digital Input) |
14 | GPO3 (Latched General Purpose Output) |
15 | A/D IN 2 (Dual Function Input) (Operation as Analog 0-16V or Digital Input is Configured via AT Command) |
16 | A/D IN 1 (Analog Input 0-16V) |
Die USB Abschirmung und die Masse sollen mit pin 6 (ground) verbunden werden, die Positive USB Leitung wird an Pin 12(Vbus) angeschlossen.
Offizielle Anleitungen
- File:Mt2500 quick start guide.pdf
- File:GSM2418UG001 - MT 2500 User Guide.pdf
- File:AT-Commands.pdf
- File:Programmingenfora.pdf
Erkenntnisse
- Auf dem Tracker ist ein Kleber der sagt dass man das Gerät an die Stromversorgung anschliessen muss bevor man den USB Stecker einsteckt. Es geht nichts kaputt wenn man diesen Hinweis nicht beachtet, aber der Tracker startet im Firmware upload Modus.
- Der tracker emuliert drei serielle CDC Schnittstellen, leider funktionieren diese nur mit Windows, weil das Linux Modul die USB ID nicht kennt(?)
- Der erste serielle Port wird für debug informationen benutzt, am zweiten Port kann das Gerät programmiert werden. Der zweck des dritten Ports ist nicht bekannt.
- Der Tracker dürfte mit dem internen Akku zwischen 3h (GPS und GSM im dauerbetrieb) und 14h (GPS und GSM im standby) laufen.
Programmierung
Ein Positionsupdate alle 60s oder 100m schicken:
at&f at&w at+cgdcont=1,"IP","internet","",0,0 at%cgpco=1,"new,new",0 at$friend=1,1,"Dest IP" at$udpapi=,Dest Port at$wakeup=0,1 at$evtim1=60 at$evtim2=1200 at$event=12,1,12,1,1 at$event=12,3,40,0,4350 at$event=13,0,16,100,1000000 at$event=13,3,43,2,0 at$event=13,3,40,0,4350 AT$areg=2 at&w
[...]